Atenţie! Înainte de a cumpăra, verificați caracteristicile și configurația mărfii cu vânzătorul. Aspectul mărfurilor și / sau ambalajelor poate fi modificat de producător și diferă de cele afișate pe site-ul web Cosmo Technology ©
UPS Tuncmatik HI-TECH Ultra X9 40 kVA DSP LCD 3P/3P Online, without batteries
http://www.tuncmatik.com/ru/product/overview/hi-tech-ultra-40-kva.html
Input
Phase : 3 phase 4 wire and ground
Nominal voltage : 380/400/415 VAC
Voltaj range : 208~478 VAC
Frequency range : 45-55Hz de 50Hz/54-66Hz at 60Hz (auto sensing)
Current THDi : ?3% (100% nonlinear load)
Bypass voltage range : Max. voltage
Power factor : ?0.99
Output
Phase : 3 phase 4 wire and ground
Nominal voltage : 380/400/415 VAC,
Power factor : 0.9
Voltage regulation : ± 1%
Frequency Normal mode : ± 1%, ± 2%, ± 4%, ± 5%, ± 10% of the rated frequency (optional)
Frequency Battery mode : (50/60±0.2%) Hz
Crest factor : 3/1
THD : ?2% with linear load, ?5% with non linear load
Efficieny : 94%
Battery
Voltage : Standard unit.±240Vdc (4x20 ad. 12V7Ah) Long run unit optional voltage.±192V/±204V/±216V/±240VDC (32/34/36/38/40pcs)
Charge current (A) (charge current can be set according to battery capacity installed : Long run unit. Max. current 10A
Transfer time : Utility to battery. 0ms; Utility to bypass. 0ms
Protection
Overload AC mode : Loads ?110%. last 60min, ?125%. last 10min, ?150%. last 1min, >150% change to bypass immediately
Overload Battery mode : Loads ?110%. last 10min, ?125%. last 1min, ?150%. >150% shut down UPS immediately
Overload Bypass mode : Breaker 80A
Short circuit 164 peak :
Over temperature Line mode : Switch to bypass, Backup mode
Battery low Alarm and switch off :
Self-diagnostic Upon power on and software control :
EPO (optional) Shut down UPS immediately :
Battery Advanced battery management :
Noise suppression Complies with EN62040-2
Indicators & Alarm
Status LED & LCD : Line mode, Bypass mode, Battery low, Battery bad, Overload & UPS fault
LCD panel : Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage & Inner temperature
Audible & Visual : Line failure, Battery low, Overload, System fault
Management
Operating systems : Windows® 98/2000/2003/XP/Vista/2008, Windows? 7/8, Linux, MAC
Interface : RS 485, USB, Paralel (Optional), Dry contact, Intelligent slot, SNMP adapter (Optional), Relay card (Optional)
Dimensions & Weight
D x G x Y (mm) : 828 x 250 x 868
Weight(kg) : 73
http://www.tuncmatik.com/ru/product/overview/hi-tech-ultra-40-kva.html
Input
Phase : 3 phase 4 wire and ground
Nominal voltage : 380/400/415 VAC
Voltaj range : 208~478 VAC
Frequency range : 45-55Hz de 50Hz/54-66Hz at 60Hz (auto sensing)
Current THDi : ?3% (100% nonlinear load)
Bypass voltage range : Max. voltage
Power factor : ?0.99
Output
Phase : 3 phase 4 wire and ground
Nominal voltage : 380/400/415 VAC,
Power factor : 0.9
Voltage regulation : ± 1%
Frequency Normal mode : ± 1%, ± 2%, ± 4%, ± 5%, ± 10% of the rated frequency (optional)
Frequency Battery mode : (50/60±0.2%) Hz
Crest factor : 3/1
THD : ?2% with linear load, ?5% with non linear load
Efficieny : 94%
Battery
Voltage : Standard unit.±240Vdc (4x20 ad. 12V7Ah) Long run unit optional voltage.±192V/±204V/±216V/±240VDC (32/34/36/38/40pcs)
Charge current (A) (charge current can be set according to battery capacity installed : Long run unit. Max. current 10A
Transfer time : Utility to battery. 0ms; Utility to bypass. 0ms
Protection
Overload AC mode : Loads ?110%. last 60min, ?125%. last 10min, ?150%. last 1min, >150% change to bypass immediately
Overload Battery mode : Loads ?110%. last 10min, ?125%. last 1min, ?150%. >150% shut down UPS immediately
Overload Bypass mode : Breaker 80A
Short circuit 164 peak :
Over temperature Line mode : Switch to bypass, Backup mode
Battery low Alarm and switch off :
Self-diagnostic Upon power on and software control :
EPO (optional) Shut down UPS immediately :
Battery Advanced battery management :
Noise suppression Complies with EN62040-2
Indicators & Alarm
Status LED & LCD : Line mode, Bypass mode, Battery low, Battery bad, Overload & UPS fault
LCD panel : Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage & Inner temperature
Audible & Visual : Line failure, Battery low, Overload, System fault
Management
Operating systems : Windows® 98/2000/2003/XP/Vista/2008, Windows? 7/8, Linux, MAC
Interface : RS 485, USB, Paralel (Optional), Dry contact, Intelligent slot, SNMP adapter (Optional), Relay card (Optional)
Dimensions & Weight
D x G x Y (mm) : 828 x 250 x 868
Weight(kg) : 73
Default | |
Tip de dispozitiv | Устройства бесперебойного питания |
Marca | Tuncmatik |
UPS Tuncmatik HI-TECH Ultra X9 40 kVA DSP LCD 3P/3P Online, without batteries
- Producător: Tuncmatik
- Cod furnizor: 1034-00007242
- Disponibilitate: În Stoc!
-
105 080 MDL
Etichete: UPS Tuncmatik HI-TECH Ultra X9 40 kVA DSP LCD 3P/3P Online, without batteries
Recomandat
32GB DDR5-4800MHz SODIMM Kingston FURY Beast (KF548S38IB-32), CL38, 1.1V, Intel XMP 3.0, Black Capacitatea Memoriei (Total): 32GB Tip Memorie: DDR5 SDRAM Frecven?a memorie: 4800 MHz Laten?a CAS:
32GB DDR5-4800MHz SODIMM Kingston FURY Beast (KF548S38IB-32), CL38, 1.1V, Intel XMP 3.0, BlackCapaci..
2 240 MDL
.M.2 NVMe SSD 1.0TB Kingston FURY Renegade w/Heatsink10.5mm [PCIe 4.0 x4, R/W:7300/6000MB/s, 3D TLC]
.M.2 NVMe SSD 1.0TB Kingston FURY Renegade w/Heatsink10.5mm [PCIe 4.0 x4, R/W:7300/6000MB/s, 3D TLC]..
2 668 MDL